    題名: Development of a spherical ultrasound transducer for transcranial low-dose ultrasound hyperthermia used in brain tumor nanodrug delivery
    作者: Shen, CC;Chen, GS;Chen, YY;Lin, WL
    貢獻者: Institute of Biomedical Engineering and Nanomedicine
    摘要: Previous studies showed that low-dose focused ultrasound hyperthermia (UH) could enhance the delivery and therapeutic efficacy of nanodrug for brain metastasis of breast cancer. In this study, our purpose is to design an ultrasound transducer that can be used for clinical application for brain tumor nanodrug delivery. Computer simulation has been used to calculate the pressure field, temperature distribution and thermal dose in the brain for different parameters of a spherical array ultrasound transducer. An ultrasound transducer with 112 disc elements (1, MHz, 2, cm in diameter) was constructed and its heating ability was characterized using a skull phantom filled with hydrogel. The simulation results showed that the position of peak pressure was slightly offset when the transducer was mechanically moved 3, cm away from the center point in all directions. There was no significant side-lobe developed when the transducer was moved away from the center 2, cm. Temperature distribution showed that the heating zone was an ellipsoid with temperature higher than 42 °C for a maximum intensity of 121, W/cm2. Phantom experiment showed that the 42 °C color-changeable hydrogel would turn to be white at the focal point when the transducer was moved 2, cm in all directions with an electrical power 55, W. A spherical ultrasound phased array was developed and characterized, and the results showed that this ultrasound transducer has the potential used in transcranial short-time ultrasound hyperthermia for brain tumor nanodrug delivery.
    日期: 2019-05-30
    關聯: World Congress on Medical Physics and Biomedical Engineering 2018. 2019 May;30:655-661.
    Link to: http://dx.doi.org/10.1007/978-981-10-9023-3_121
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000449744300121
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85048260168
    顯示於類別:[陳景欣] 會議論文/會議摘要

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    SCP85048260168.pdf729KbAdobe PDF364檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋