國家衛生研究院 NHRI:Item 3990099045/11562
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 12189/12972 (94%)
造訪人次 : 956436      線上人數 : 861
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於NHRI管理 到手機版
    請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/11562


    題名: Mechanical performance of conical implant-abutment connections under different cyclic loading conditions
    作者: Yao, KT;Kao, HC;Cheng, CK;Fang, HW;Huang, CH;Hsu, ML
    貢獻者: Institute of Biomedical Engineering and Nanomedicine
    摘要: OBJECTIVES: Conical implant-abutment connections are popular for its anti-bending performance; on the other hand, the torsional and axial forces also play important roles in occlusion. However, so far there were scarce studies on their effects on connection stability. Therefore, this study seeks to investigate the mechanical performance of conical connections under different cyclic loading conditions. METHODS: 15 conical implant-abutment assembles (Cowell Medi, Busan, South Korea) were divided into 3 groups according to different cyclic loadings. In group BTA, the loading condition of the posterior occlusion was simulated (20-200N, 30 degrees off-axis and 4mm eccentric to implant axis), generating a bending moment, a torsional moment, and an axial loading. In group BT, a bending moment and a torsional moment of the posterior occlusion were applied (10-100N, 90 degrees off-axis and 4mm eccentric to implant axis). In group B, only a bending moment was applied (10-100N, 90 degrees off-axis and through implant axis). The fatigue testing machine ran at 10Hz until failure, or to the upper limit of 10(6) cycles. The fatigue cycles and failure modes were recorded. Besides, the value of the torque loss of the abutment screw, the difference between initial torque and post-load reverse torque, was calculated. The data were statistically analyzed. Morphologies of the abutment conical surface were examined by scanning electron microscopy. RESULTS: In group B and BTA, all samples passed the test (10(6) cycles). While, in group BT, all abutments generated rotation within 140 cycles, showing significant differences compared to the other two groups (p<0.001). However, from SEM observations, both group B and BT showed marked fretting wear, indicating obvious micromotion in the connection. Whereas group BTA showed indentation of tight contact, attributed to the axial loading. In terms of the torque loss of the abutment screw, the torque loss in group BT was much more than the other two groups with statistically significant differences (p<0.05). CONCLUSION: Owing to the effect of the bending moment, marked fretting wear was generated in the conical connections and further led to loss of the anti-torsional ability. However, adding an axial loading could improve their anti-torsional ability significantly.
    日期: 2019-02
    關聯: Journal of the Mechanical Behavior of Biomedical Materials. 2019 Feb;90:426-432.
    Link to: http://dx.doi.org/10.1016/j.jmbbm.2018.10.039
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=1751-6161&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000457510500047
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85056608886
    顯示於類別:[其他] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    PUB30445369.pdf2127KbAdobe PDF366檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋