國家衛生研究院 NHRI:Item 3990099045/11819
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 12189/12972 (94%)
造訪人次 : 955349      線上人數 : 684
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於NHRI管理 到手機版
    請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/11819


    題名: Diagnosing the RGS11 lung cancer biomarker: The integration of competitive immunoassay and isothermal nucleic acid exponential amplification reaction
    作者: Chang, YF;Huang, YQ;Wu, KM;Jou, AFJ;Shih, NY;Ho, JAA
    貢獻者: National Institute of Cancer Research
    摘要: Lung cancer is the primary cause of cancer associated mortality worldwide, which makes the identification of reliable lung cancer biomarkers a pressing need for early diagnosis and prognosis. RGS11, which is a regulator of G-protein signaling and also a lung cancer biomarker, plays an important role in cancer-related metastasis. However, trace levels of RGS11 (in the range of pg/mL) in serum samples make it difficult to quantify using currently available enzyme linked immunosorbent assay (ELISA) kits and, therefore, this hinders progress in the discovery of new approaches for treating lung cancer. The aim of this study is to develop a rapid, sensitive, and reliable platform for the detection of RGS11 lung cancer biomarker based on a suspension immunoassay coupled with an isothermal exponential amplification strategy. Our study was initiated by the functionalization of magnetic beads with anti-RGS11 antibodies (Ab-MB) by EDC (1-ethyl-3-(3-(dimethylamino)propyl)-carbodiimide)/NHS (N-hydroxysulfosuccinimide) activation. Ab-MB served as a sensing probe for the competitive immunorecognitions between known concentrations of His-tag RGS11 and unknown concentrations of target RGS11 in serum. The reporter anti-His antibodies, which were modified with primers that induced an isothermal exponential amplification reaction, were subsequently introduced to the reaction mixture that resulted in the formation of immunosandwich complexes. The exponentially amplified DNA duplex that was intercalated with SYBR Green was designated as a signal reporter for the assessment of RGS11 in an inversely proportional relationship. The sensing platform was excellent for the determination of RGS11 with an exceptional detection limit of 148 fg/mL and a linear dynamic range of 0.1-10 pg/mL using a minimal sample volume (20 mu L) and with a reaction time of 1.5 h. In addition, we challenged the sensing platform with RGS11-spiked samples (in 2x diluted serum), and an acceptable recovery rate (>90%) was observed. Finally, 24 clinical samples acquired from patients with advanced lung cancer (C), inflammation (I), and heart failure (H) were analyzed by this newly developed sensing platform and a commercial ELISA kit for validation. This sensing platform has potential in biomedical applications for clinically diagnosing liquid biopsy samples for patients with lung cancer. Moreover, the universal design of our proposed system is easily adapted to detect any other protein if a His-tag recombinant protein is available.
    日期: 2019-03
    關聯: Analytical Chemistry. 2019 Mar;91(5):3327-3335.
    Link to: http://dx.doi.org/10.1021/acs.analchem.8b04374
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0003-2700&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000460709200023
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85062076012
    顯示於類別:[施能耀] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    ISI000460709200023.pdf3321KbAdobe PDF290檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋