 |
English
|
正體中文
|
简体中文
|
Items with full text/Total items : 12500/13673 (91%)
Visitors : 2480655
Online Users : 286
|
|
|
Loading...
|
Please use this identifier to cite or link to this item:
http://ir.nhri.org.tw/handle/3990099045/11889
|
Title: | Effects of signal averaging, gradient encoding scheme, and spatial resolution on diffusion kurtosis imaging: An empirical study using 7T MRI |
Authors: | Chiang, CW;Lin, SY;Cho, KH;Wu, KJ;Wang, Y;Kuo, LW |
Contributors: | Institute of Biomedical Engineering and Nanomedicine;Center for Neuropsychiatric Research |
Abstract: | BACKGROUND: Although diffusion gradient directions and b-values have been optimized for diffusion kurtosis imaging (DKI), little is known about the effect of signal averaging on DKI reliability. PURPOSE: To evaluate how signal averaging influences the reliability of DKI indices using two gradient encoding schemes with three spatial resolutions. STUDY TYPE: Prospective. ANIMAL MODEL: Fifteen naive Sprague-Dawley rats. FIELD STRENGTH/SEQUENCE: DKI was performed at 7T using two schemes (30 directions with three b-values [30d-3b] and six directions with 15 b-values [6d-15b]), three resolutions, and eight repetitions. ASSESSMENT: DKI reliability was assessed using voxelwise relative error (sigma) and test-retest error of fractional anisotropy (FA), mean diffusivity (MD), and mean kurtosis (MK) within gray matter (GM) and white matter (WM). The number of excitations (NEX) was optimized by considering DKI reliability. The influence of the partial volume effect (PVE) was also assessed. STATISTICAL TEST: One-way analysis of variance. RESULTS: The 30d-3b scheme, compared with the 6d-15b scheme, exhibited apparently smaller sigmaFA and sigmaMK (eg, at NEX 1, in GM, for three resolutions, sigmaFA : 19.9-38.2% vs. 34.2-61.4%, sigmaMK : 6.9-11.4% vs. 14.1-15.4%) and similar sigmaMD (all differences between two schemes <1.6%). The optimal NEX was determined as 2 for enabling a reliable measurement of DKI-derived indices. The PVE at the lowest resolution apparently increased sigmaFA for both schemes (19.9% for 30d-3b and 34.2% for 6d-15b) and sigmaMK for the 6d-15b scheme (14.7%) in GM, and exerted lower effects on MK values for the 30d-3b scheme (P > 0.05). DATA CONCLUSION: A higher number of diffusion directions would benefit FA and MK estimation. A higher spatial resolution helps to reduce PVE. By using the 30d-3b scheme, MK is considered a robust index to reflect microstructural changes in GM and WM. We propose a systematic approach to determine the optimal DKI protocols for appropriate preclinical settings. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019. |
Date: | 2019-11 |
Relation: | Journal of Magnetic Resonance Imaging. 2019 Nov;50(5):1593-1603. |
Link to: | http://dx.doi.org/10.1002/jmri.26755 |
JIF/Ranking 2023: | http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=1053-1807&DestApp=IC2JCR |
Cited Times(WOS): | https://www.webofscience.com/wos/woscc/full-record/WOS:000490258000023 |
Cited Times(Scopus): | https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85064548139 |
Appears in Collections: | [郭立威] 期刊論文 [王昀] 期刊論文
|
Files in This Item:
File |
Size | Format | |
PUB30990956.pdf | 1816Kb | Adobe PDF | 354 | View/Open |
|
All items in NHRI are protected by copyright, with all rights reserved.
|