國家衛生研究院 NHRI:Item 3990099045/11891
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12500/13673 (91%)
造访人次 : 2622774      在线人数 : 590
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/11891


    题名: Wearable inverse light-emitting diode sensor for measuring light intensity at specific wavelengths in light therapy
    作者: Tsai, HY;Su, FC;Chou, CH;Lin, YH;Huang, KC;Yang, YJJPD;Kuo, LW;Liao, LD;Yu, HS
    贡献者: National Institute of Environmental Health Sciences;Institute of Biomedical Engineering and Nanomedicine
    摘要: Optical measurement is conducted by employing components such as a spectrometer or photodiode (PD) to detect light intensity. However, the size of spectrometer is large because of its complex optical path and component. Moreover, a PD usually detects the total light intensity instead of the intensity of light at a specific wavelength. Therefore, a novel inverse light-emitting diode (LED) sensor was developed to measure light intensity at specific wavelengths because of the reverse effect of LEDs. In the experiments conducted in this paper, red, green, and blue LEDs were used in combination as the inverse LED sensor and light source. Moreover, commercial equipment such as a PD, an illuminometer, a power meter, and Actiwatch 2 were simultaneously employed to detect the light intensities. The results revealed that the intensity ratio evaluated using the inverse LED sensor was proportional to that of the light source. This implies that the correlation between the incident light and measured intensities from the proposed inverse LED sensor was stronger than commercial equipment. The relationship between intensity ratio, irradiance distance, and illumination angle was also determined. The least difference between the measured and ideal evaluated intensity ratio was 2.4%. The proposed inverse LED sensor has following advantages: low cost, small size, high-wavelength selectivity, and high-intensity correlation. In a future study, light intensity can be measured using wearable devices comprising the proposed inverse LED sensor, and the presented relationship can be evaluated to investigate the effect between the light intensity and physiological mechanisms or diseases.
    日期: 2019-03-25
    關聯: IEEE Transactions on Instrumentation and Measurement. 2019 Mar 25;68(5):1561-1574.
    Link to: http://dx.doi.org/10.1109/TIM.2019.2899444
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0018-9456&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000465231600035
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85064697965
    显示于类别:[余幸司] 期刊論文
    [郭立威] 期刊論文
    [廖倫德] 期刊論文

    文件中的档案:

    档案 大小格式浏览次数
    SCP85064697965.pdf3896KbAdobe PDF649检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈