國家衛生研究院 NHRI:Item 3990099045/15011
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12500/13673 (91%)
造访人次 : 2555693      在线人数 : 427
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/15011


    题名: A randomised trial comparing drug-coated balloons and conventional balloons for the treatment of stent-graft stenosis in dialysis vascular access
    作者: Hsieh, MY;Lin, PS;Liao, MT;Lin, L;Chen, TY;Boon, JC;Yang, TF;Wu, CC
    贡献者: Institute of Cellular and Systems Medicine
    摘要: OBJECTIVE: Previous studies on arteriovenous fistulas have demonstrated the potential benefit of drug-coated balloons (DCBs) in maintaining the patency of dialysis access. However, stenoses involving stent-grafts were excluded from these studies. Therefore, we aimed to evaluate the effectiveness of DCBs in treating stent-graft stenosis. METHODS: This was a prospective, single-blinded, randomised controlled study. From March 2017 to April 2021, 40 patients with dysfunctional vascular access owing to stent-graft stenosis were randomised to treatment with a DCB or a conventional balloon. Clinical follow up was scheduled at 1, 3, and 6 months, and angiographic follow up was performed 6 months after the intervention. The primary outcome was angiographic late luminal loss at 6 months, and secondary outcomes included target lesion and access circuit primary patency at 6 months. RESULTS: Thirty-six participants completed follow up angiography. The DCB group had a superior mean late luminal loss at 6 months compared with the control group (1.82 mm ± 1.83 mm vs. 3.63 mm ± 1.08 mm, respectively, p = .001). All 40 patients completed clinical follow up. The DCB group had a superior 6-month target lesion primary patency compared with the control group [hazard ratio (HR) 0.23, 95% confidence interval (CI) 0.07 - 0.71; p = .005). Additionally, the DCB group had a numerically higher 6-month access circuit primary patency rate than the control group, although the difference was not statistically significant (HR 0.54, 95% CI 0.26 - 1.11, p = .095). CONCLUSION: Conventional balloon angioplasty is not durable in stent-graft stenosis treatment. Treatment with DCBs provides less angiographic late luminal loss and potentially superior primary patency of the target lesion than treatment with conventional balloons. [ClinicalTrials ID: NCT03360279.].
    日期: 2023-08
    關聯: European Journal of Vascular and Endovascular Surgery. 2023 Aug;66(2):253-260.
    Link to: http://dx.doi.org/10.1016/j.ejvs.2023.05.028
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=1078-5884&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:001059000900001
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85164376608
    显示于类别:[吳志成] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    PUB37209996.pdf945KbAdobe PDF161检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈