    題名: Improved accuracy of brain MRI/SPECT registration using a two-cluster SPECT normalization algorithm and a combinative similarity measure: application to the evaluation of Parkinson's disease
    作者: Lee, JD;Huang, CH;Weng, YH;Li, KJ;Chen, CT
    貢獻者: Division of Medical Engineering Research
    摘要: Objecive Single-photon emission computed tomography (SPECT) of dopamine transporters with techne- tium-99-labeled tropane derivative Tc-99m-TRODAT-1 has recently been suggested to offer valuable information in assessing the functionality of dopaminergic systems. To facilitate the non-invasive examination of the dopamine concentration in vivo, registering magnetic resonance imaging (MRI) and SPECT image is important. This article proposes a new similarity measure for MRI/SPECT registration. Methods The proposed similarity measure combines anatomic features that are characterized by specific binding of nuclear medicine and the distribution of image intensity that are characterized by the normalized mutual information (NMI). A preprocess, a novel two-cluster SPECT normalization algorithm, is also proposed. Results Compared with the conventional NMI-based registration algorithm, the proposed registration frame-work reduces the target of registration error from >7 mm to approximately 4 mm. The error of the specific-to-nonspecific Tc-99m-TRODAT-1 binding ratio (BR), a quantitative measure of TRODAT receptor binding, is also reduced from 0.45 to 0.08 in the healthy subjects and from 0.28 to 0.12 in Parkinson's disease patients. Conclusions A suitable color map, such as "rainbow," for image display enables the two-cluster SPECT normalization algorithm to provide clinically meaningful visual contrast. In addition, registering MRI/SPECT based on the proposed similarity measure improves the accuracy compared with the conventional NMI-based algorithm.
    關鍵詞: Radiology, Nuclear Medicine & Medical Imaging
    日期: 2007-06
    關聯: Annals of Nuclear Medicine. 2007 Jun;21(4):197-207.
    Link to: http://dx.doi.org/10.1007/s12149-007-0009-z
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0914-7187&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000248096500002
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=34547702746
    顯示於類別:[其他] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    ISI000248096500002.pdf487KbAdobe PDF405檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋