    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/2214


    题名: Combining multiplex reverse transcription-PCR and a diagnostic microarray to detect and differentiate enterovirus 71 and coxsackievirus A16
    作者: Chen, TC;Chen, GW;Hsiung, CA;Yang, JY;Shih, SR;Lai, YK;Juang, JL
    贡献者: Division of Molecular and Genomic Medicine;Division of Biostatistics and Bioinformatics
    摘要: Cluster A enteroviruses, including enterovirus 71 (EV71) and coxsackievirus A16 (CA16), are known to cause hand-foot-and-mouth disease (HFMD). Despite the close genetic relationship between these two viruses, EV71 is generally known to be a more perpetuating pathogen involved in severe clinical manifestations and deaths. While the serotyping of enteroviruses is mostly done by conventional immunological methods, many clinical isolates remain unclassifiable due to the limited number of antibodies against enterovirus surface proteins. Array-based assays are able to detect several serotypes with high accuracy. We combined an enterovirus microarray with multiplex reverse transcription-PCR to try to develop a method of sensitively and accurately detecting and differentiating EV71 and CA16. In an effort to design serotype-specific probes for detection of the virus, we first did an elaborate bioinformatic analysis of the sequence database derived from different enterovirus serotypes. We then constructed a microarray using 60-mer degenerate oligonucleotide probes covalently bound to array slides. Using this enterovirus microarray to study 144 clinical specimens from patients infected with HFMD or suspected to have HFMD, we found that it had a diagnostic accuracy of 92.0% for EV71 and 95.8% for CA16. Diagnostic accuracy for other enteroviruses (non-EV71 or -CA16) was 92.0%. All specimens were analyzed in parallel by real-time PCR and subsequently confirmed by neutralization tests. This highly sensitive array-based assay may become a useful alternative in clinical diagnostics of EV71 and CA16.
    关键词: Microbiology
    日期: 2006-06
    關聯: Journal of Clinical Microbiology. 2006 Jun;44(6):2212-2219.
    Link to: http://dx.doi.org/10.1128/JCM.02393-05
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0095-1137&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000238332900043
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=33745159353