國家衛生研究院 NHRI:Item 3990099045/4333
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 915102      在线人数 : 1390
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/4333


    题名: A voxel-driven system matrix design for multipinhole SPECT with overlapping projection
    其它题名: IEEE Nuclear Science Symposium Conference Record. 2009:3924-3927.
    作者: Huang, PC;Hsiao, IT;Lin, KM;Chou, WT;Hsu, CH
    贡献者: Division of Medical Engineering Research
    摘要: Single pinhole SPECT can provide high-resolution functional imaging of small animals, while multipinhole SPECT can further increase photon sampling and hence improve system sensitivity. In addition, overlapping projection of a multipinhole system can improve the overall usage of detector area, but such a multiplexing detection inevitably leads to image quality deterioration. Since iterative image reconstruction permits the incorporation of physical factors in the form of system matrix, we propose a voxel-based design which explicitly accounts for multipinhole geometry, aperture diameter, and projection overlapping. The proposed voxel-based system matrix can describe not only the entire process of photon emission from its source and through a pinhole (including voxel depth and aperture size), but also identify the pinhole channel which a photon is passing through. In addition, the projection of the central pinhole is circular, while the projections of an off-centered pinhole consists of two half ellipses. The detection probabilities of each voxel through every pinhole can be then derived from the areas of these composite ellipses. Since the areas also depend on the depth of voxel to pinhole and aperture diameter, the voxel-driven model is also depth-dependent and sensitive. We investigate the performance improvement of the proposed model compared to the traditional ray-tracing model. In terms of spatial resolution, the proposed model can achieve a better resolution uniformity through the field of view.
    日期: 2009-10-25
    關聯: Nuclear Science Symposium Conference Record, 2009 IEEE. 2009 Oct 25:3924-3927.
    Link to: http://dx.doi.org/10.1109/NSSMIC.2009.5401937
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000280505102119
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=77951157278
    显示于类别:[林名釗] 會議論文/會議摘要

    文件中的档案:

    档案 描述 大小格式浏览次数
    SCP77951157278.pdf261KbAdobe PDF844检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈