國家衛生研究院 NHRI:Item 3990099045/4836
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 12145/12927 (94%)
造訪人次 : 917548      線上人數 : 1363
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於NHRI管理 到手機版
    請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/4836


    題名: Least-square pinhole SPECT calibration using a forward projector modeling misalignment
    其他題名: 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
    作者: Wietholt, C;Chen, CT;Fu, G;Meng, LJ
    貢獻者: Division of Medical Engineering Research
    摘要: Recent improvements in detector technology allow pinhole SPECT to approach spatial resolutions as low as 50 μm. Such high resolutions require a high accuracy of the imaging gantry for preclinical SPECT systems, and is not easily achieved in a laboratory setting. Analytical calibration methods are deemed to fail due to practical implications such as size and activity concentrations of the required point sources. Thus, we have developed a numerical calibration method based on leastsquare optimization that incorporates the modeling attributes of a forward projector frequently used in iterative reconstruction. The forward projector is currently capable of modeling detector misalignment such as detector rotation and pinhole translation, and will incorporate the pinhole point spread function as well as the size and shape of the point source. Currently, our calibration phantom consists of a single point source, positioned off-center in the object space. The optimization method involves a sequentially fitting of each individual parameter to the data, followed by fitting multiple parameters simultaneous in consecutive steps including all five parameters for the final fitting. The results of the optimization show an error of expected magnitude considering the relatively coarse sampling grid of our simulations. The relatively slow convergence of the y- and z-tilt require simulation of additional point sources. Further improvements of computational and memory efficiency need to be made, which enable the method to fit high resolution data as well as incorporation of the pinhole point spread function and the shape and size of the point sources.
    日期: 2007-10
    關聯: Nuclear Science Symposium Conference Record, 2007 IEEE. 2007 Oct;6:4543-4545(Article number 4437121).
    Link to: http://dx.doi.org/10.1109/NSSMIC.2007.4437121
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000257380403147
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=48149091265
    顯示於類別:[其他] 會議論文/會議摘要

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    SCP48149091265.pdf112KbAdobe PDF793檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋