國家衛生研究院 NHRI:Item 3990099045/4853
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 851708      在线人数 : 1011
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/4853


    题名: Simultaneous multi-slice acquisition using a parallel MR imaging system
    其它题名: 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
    作者: Tai, HK;Kuo, LW;Lin, YP;Yao, C;Chen, JH
    贡献者: Division of Medical Engineering Research
    摘要: In this study, we attempt to reduce the Magnetic Resonance Imaging (MRI) scan time by combining Simultaneous Multi-slice Acquisition (SIMA) and blind source separation method in a phased array MR acquisition system[1-6]. Imaging was first acquired by a typical parallel imaging MR with multi-slice excitation RF profile; this will ends up with an overlapped image. By using blind source separation method which is addressed by Larkman [7] with information of these coil sensitivity distribution, one can further achieve n multiple slice images. The overall reduction ratio in acquisition time then will be the traditional reduction ratio R times this slice number n. By increasing the acceleration factor of Parallel Imaging, the SNR which involves ill-condition problem dropped severely and induce the obvious noise amplification in this reconstruction process [8-10]. Tikhonov regularization is then employed to treat this ill-condition problem. In the preliminary study, we have successfully implement this technology by exciting two slices simultaneously in addition to the reduction factor R = 2 for a parallel MR system in in vivo experiment. In the conference, we will show results with higher number of slice number n for high spatiotemporal resolution on MR imaging system. In the future, more excited slices will be applied to this technique and the dynamic functional studies will also be used to test its capability.
    日期: 2005-01
    關聯: 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005. 2005 Jan;7 1652-1655.
    Link to: http://dx.doi.org/10.1109/IEMBS.2005.1616757
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000238998401156
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=33846895694
    显示于类别:[姚晶(2001-2014)] 會議論文/會議摘要

    文件中的档案:

    档案 描述 大小格式浏览次数
    SCP33846895694.pdf380KbAdobe PDF878检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈