國家衛生研究院 NHRI:Item 3990099045/5298
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 910889      在线人数 : 930
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/5298


    题名: Effects of ambient particulate matter and fungal spores on lung function in schoolchildren
    作者: Chen, BY;Chao, HJ;Chan, CC;Lee, CT;Wu, HP;Cheng, TJ;Chen, CC;Guo, YL
    贡献者: Division of Biostatistics and Bioinformatics
    摘要: OBJECTIVES: Studies examining the combined health effects of both have been relatively lacking. We conducted a longitudinal study to investigate whether exposure to air pollutants and fungal spores might exacerbate childhood respiratory health.METHODS: Study participants were 100 elementary and middle-school students in Taipei County, Taiwan. A structured respiratory health questionnaire was administered in September 2007, followed by monthly spirometry from October 2007 to June 2008. During the study period, complete daily monitoring data for criteria air pollutants were obtained from the Environmental Protection Administration monitoring station and Aerosol Supersite. Fungal spores were measured from Sunday to Saturday in the week when lung-function measurements were made for each study month. Lung-function measurements were compared with air pollutants and fungal spores using mixed-effects models with 1-day-lag modeling.RESULTS: The particulate matter with an aerodynamic diameter of 2.5 mu m or less level 1 day before the lung function measurements was negatively associated with forced vital capacity. The fungal spore level was negatively associated with both forced expiratory vital capacity and forced expiratory volume in 1 second. O-3 level was negatively associated with forced expiratory flow at 25%, 50%, and 75% of forced vital capacity, and average expiratory flow over the middle half of forced vital capacity.CONCLUSIONS: This study suggested that exposure to particulate matter with an aerodynamic diameter of 2.5 mu m or less and fungal spores might cause adverse effects on the vital capacity of schoolchildren. Exposure to O-3 adversely affected small airway function.
    日期: 2011-03
    關聯: Pediatrics. 2011 Mar;127(3):e690-e698.
    Link to: http://dx.doi.org/10.1542/peds.2010-1038
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0031-4005&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000287845400020
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=79952222935
    显示于类别:[陳主智] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    PB2010123001.pdf1377KbAdobe PDF752检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈