國家衛生研究院 NHRI:Item 3990099045/5635
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12189/12972 (94%)
造访人次 : 955604      在线人数 : 767
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/5635


    题名: Efficient method for generating a pinhole edge penetration model for iterative reconstruction using GATE
    其它题名: IEEE Nuclear Science Symposium Conference Record
    作者: Wietholt, C
    贡献者: Division of Medical Engineering Research
    摘要: The ability to acquire images with resolutions in the micrometer range, as recently reported for pinhole and multipin-hole SPECT systems, raised interest in these imaging modalities within the preclinical small animal imaging research community. At such high resolutions, physical imaging properties such as pinhole edge penetration, detector blur, detector misalignment, the geometric response of the aperture, and gamma photon attenuation and scatter can severely degrade image quality. To improve system design and reconstruction methods, an aperture edge penetration model was developed. The model was simulated in GATE by replacing each imaging detector element with a point source and collecting the photons emitted by this source on the opposite side of the aperture. For efficiency, only one detector quadrant was evaluated and sampling of the model was performed for every fourth detector element. Furthermore, the photons were focused onto the aperture by adjusting the polar and azimuthal emission angles. Models were developed for two imaging systems using 2 different isotopes (Tc99m & I-125). The first system had a detector size of 260 mm and a pinhole-to-detector distance of 180 mm. The second had a detector size of 90 mm and a pinhole-to-detector distance of 100 mm. The same aperture was used for both systems. The system with the larger detector showed an enlargement in effective pinhole size inversely proportional to the distance between detector center and detector element, whereas the smaller detector showed a similar dependence at a reduced amplitude. For I-125, the effective pinhole size was similar to the bore diameter, since only a small number of the low energy photons penetrated through the aperture material. This simulation of the aperture edge penetration will aid in better understanding pinhole SPECT system design that minimize the penetration effects, as well as for development of more accurate reconstruction algorithms.
    日期: 2006-10
    關聯: Nuclear Science Symposium Conference Record, 2006. IEEE. 2006 Oct;6:3899-3903.
    Link to: http://dx.doi.org/10.1109/NSSMIC.2006.353841
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000288875603211
    显示于类别:[其他] 會議論文/會議摘要

    文件中的档案:

    档案 描述 大小格式浏览次数
    ISI000288875603211.pdf178KbAdobe PDF421检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈