    題名: AlGaN/GaN high electron mobility transistors for protein-peptide binding affinity study
    作者: Huang, CC;Lee, GY;Chyi, JI;Cheng, HT;Hsu, CP;Hsu, YR;Hsu, CH;Huang, YF;Sun, YC;Chen, CC;Li, SS;Andrew Yeh, J;Yao, DJ;Ren, F;Wang, YL
    貢獻者: Division of Medical Engineering Research
    摘要: Antibody-immobilized AlGaN/GaN high electron mobility transistors (HEMTs) were used to detect a short peptide consisting of 20 amino acids. One-binding-site model and two-binding-site model were used for the analysis of the electrical signals, revealing the number of binding sites on an antibody and the dissociation constants between the antibody and the short peptide. In the binding-site models, the surface coverage ratio of the short peptide on the sensor surface is relevant to the electrical signals resulted from the peptide–antibody binding on the HEMTs. Two binding sites on an antibody were observed and two dissociation constants, 4.404×10−11 M and 1.596×10−9 M, were extracted from the binding-site model through the analysis of the surface coverage ratio of the short peptide on the sensor surface. We have also shown that the conventional method to extract the dissociation constant from the linear regression of curve-fitting with Langmuir isotherm equation may lead to an incorrect information if the receptor has more than one binding site for the ligand. The limit of detection (LOD) of the sensor observed in the experimental result (∼10 pM of the short peptide) is very close to the LOD (around 2.7–3.4 pM) predicted from the value of the smallest dissociation constants. The sensitivity of the sensor is not only dependent on the transistors, but also highly relies on the affinity of the ligand-receptor pair. The results demonstrate that the AlGaN/GaN HEMTs cannot only be used for biosensors, but also for the biological affinity study.
    日期: 2013-03
    關聯: Biosensors and Bioelectronics. 2013 Mar;41:717-722.
    Link to: http://dx.doi.org/10.1016/j.bios.2012.09.066
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0956-5663&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000314191300107
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84870823009
    顯示於類別:[許佳賢] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    SDO0956566312006720.pdf627KbAdobe PDF511檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋