國家衛生研究院 NHRI:Item 3990099045/8431
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 12145/12927 (94%)
Visitors : 909284      Online Users : 778
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: http://ir.nhri.org.tw/handle/3990099045/8431


    Title: A moveable surface coil fabrication for MR-guided HIFU ablation
    Authors: Hwang, SC;Chang, H;Kuo, IY;He, PH
    Contributors: Institute of Biomedical Engineering and Nanomedicine
    Abstract: Background: In this study, a moveable MRI receive-only surface coil was fabricated and used to provide higher SNR MRI images focused on a small area. The moveable coil can be moved together with the HIFU transducer to improve the accuracy of MRI temperature measurement of HIFU ablation in a mini-pig model. Materials and methods A movable circle surface coils with a low input impedance preamplifier were made to connect the receive system of a 1.5T MRI scanner (Symphony, Siemens). The coil was moved together with the HIFU transducer during the HIFU ablation. The dynamic temperature images during HIFU ablation of porcine meat and living mini-pig leg were measured by this home-made coil. MR temperature measurements were calculated based on proton resonance frequency (PRF) shift method. A spoiled gradient echo sequence was applied for temperature mapping (TR = 13ms, TE = 7 ms, flip angle = 30 deg, matrix 128x128, FOV= 256 x 256 mm, slice thickness = 8 mm). Results: The SNR ratio using our coil was improved at least 3 times than using the commercial spinal coil array for the case of pig leg HIFU ablation since the coil is more closely to the target. The standard deviations of temperature measured by the moveable surface coils were 0.3, 0.6 deg C for porcine meat and pig leg, respectively. Conclusions: The results of our HIFU studies showed that the MRI image signal-to-noise ratio was improved and thus the higher precision of the temperature measurement could be obtained. It showed the advantage and feasibility of using a smaller and mobile surface coil for MR-guided HIFU ablation.
    Date: 2014-12-10
    Relation: Journal of Therapeutic Ultrasound. 2014 Dec 10;2(Suppl. 1):A20.
    Link to: http://dx.doi.org/10.1186/2050-5736-2-S1-A20
    Appears in Collections:[Hsu Chang(2004-2017)] Conference Papers/Meeting Abstract

    Files in This Item:

    File Description SizeFormat
    BMC2015010102.pdf88KbAdobe PDF585View/Open


    All items in NHRI are protected by copyright, with all rights reserved.

    Related Items in TAIR

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback