國家衛生研究院 NHRI:Item 3990099045/9510
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 856709      在线人数 : 837
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/9510


    题名: Prolonged postprocedural outbreak of Mycobacterium massiliense infections associated with ultrasound transmission gel
    作者: Cheng, A;Sheng, WH;Huang, YC;Sun, HY;Tsai, YT;Chen, ML;Liu, YC;Chuang, YC;Huang, SC;Chang, CI;Chang, LY;Huang, WC;Hsueh, PR;Hung, CC;Chen, YC;Chang, SC
    贡献者: Division of Infectious Diseases
    摘要: Background postprocedural infections by Mycobacterium abscessus complex are increasing worldwide and the source and route of transmission are infrequently identified. Here the extension of a previous clustering of paediatric patients with surgical site infections due to a single strain of the subspecies M. massiliense is reported. Methods Investigation conducted at a 2200-bed teaching hospital in Taiwan including microbial surveillance of the environment (water, air, equipment and supplies) and a case-control study. We performed molecular identification and typing of the isolates by a trilocus sequencing scheme, confirmed by multilocus sequencing typing (MLST) and pulsed-field gel electrophoresis (PFGE). Results We investigated 40 patients who developed post-procedure, soft tissue or bloodstream infections by M. massiliense (TPE101), during a 3-year period. 38 patients were identified at hospital A, one newborn and her mother were identified at hospital B (185 kilometers from hospital A). A case-control study identified the association of invasive procedures (adjusted odds ratio [aOR] 9.13) and ultrasonography (aOR 2.97) (both p<0.05) with acquiring the outbreak strain. Isolates from the cases and unopened bottles of ultrasound transmission gel were all ST48 and indistinguishable or closely related by PFGE. After replacement of contaminated gel, no new cases have been detected in the 18 months of follow-up. Conclusions This investigation identified the use of contaminated gel as the common source causing an outbreak on a larger scale than had been recognised. Our findings halted production by the manufacturer and prompted revision of hospital guidelines.
    日期: 2016-04
    關聯: Clinical Microbiology and Infection. 2016 Apr;22(4):382.e1-382.e11.
    Link to: http://dx.doi.org/10.1016/j.cmi.2015.11.021
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=1198-743X&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000375399900019
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84963725764
    显示于类别:[陳宜君] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    SDO1198743X16000021.pdf675KbAdobe PDF799检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈