國家衛生研究院 NHRI:Item 3990099045/2498
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 858624      在线人数 : 645
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/2498


    题名: Clinical-scale high-throughput analysis of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine by isotope-dilution liquid chromatography-tandem mass spectrometry with on-line solid-phase extraction
    作者: Hu, CW;Wang, CJ;Chang, LW;Chao, MR
    贡献者: Division of Environmental Health and Occupational Medicine
    摘要: Background: Quantification of 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) in urine or blood is used to assess and monitor oxidative stress in patients. We describe the use of on-line solid-phase extraction (SPE) and isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) for automated measurement of urinary 8-oxodGuo. Methods: Automated purification of urine was accomplished with a switching valve and an Inertsil ODS-3 column. After the addition of N-15(5) labeled 8-oxodGuo as an internal standard, urine samples were analyzed within 10 min without sample purification. This method was applied to measure urinary 8-oxodGuo in a group of healthy persons (32 regular smokers and 35 nonsmokers). Urinary cotinine was also assayed by an isotope-dilution LC-MS/MS method. Results: The lower limit of detection was 5.7 ng/L on column (2.0 fmol). Inter- and intraday imprecision (CV) was < 5.0%. Mean recovery of 8-oxodGuo in urine was 99%-102%. Mean (SD) urinary concentrations of 8-oxodGuo in smokers [7.26 (3.14) mu g/g creatinine] were significantly higher than those in nonsmokers [4.69 (1.70) mu g/g creatinine; P < 0.005]. Urinary concentrations of 8-oxodGuo were significantly correlated with concentrations of cotinine in smokers (P < 0.05). Conclusions: This on-line SPE LC-MS/MS method is sufficiently sensitive, precise, and rapid to provide high-throughput direct analysis of urinary 8-oxodGuo without compromising quality and validation criteria. This method could be applicable for use in daily clinical practice for assessing oxidative stress in patients.
    关键词: Medical Laboratory Technology
    日期: 2006-07
    關聯: Clinical Chemistry. 2006 Jul;52(7):1381-1388.
    Link to: http://dx.doi.org/10.1373/clinchem.2005.063735
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0009-9147&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000238725800023
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=33745448772