English  |  正體中文  |  简体中文  |  Items with full text/Total items : 12145/12927 (94%)
Visitors : 848282      Online Users : 924
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: http://ir.nhri.org.tw/handle/3990099045/8396


    Title: Determination of the maleic acid in rat urine and serum samples by isotope dilution-liquid chromatography-tandem mass spectrometry with on-line solid phase extraction
    Authors: Chen, HC;Wu, C;Wu, KY
    Contributors: National Environmental Health Research Center
    Abstract: A rapid and simple on-line solid-phase extraction coupled with isotope dilution-liquid chromatography-tandem mass spectrometry (SPE-ID-LC-MS/MS) method was developed to quantitate maleic acid in serum and urine of Sprague Dawley (SD) rats. The aforementioned biological samples were spiked with 13C2-maleic acid, vigorously vortexed, added with acetonitrile to precipitate proteins, and then injected into the on-line SPE LC-MS/MS system for quantification. Upon validation, this method demonstrated excellent feasibility and sensitivity: Calibration curves for maleic acid in serum and urine display excellent linearity with the coefficient of determination (R2) greater than 0.999, the limits of detection and quantitation (LOD and LOQ) for maleic acid were determined at 0.2 and 0.5 μg L?1, respectively. Additionally, intra-day accuracy for maleic acid in serum and urine samples ranged from 94.0 to 100.2% and 101.3 to 104.4%, respectively. Furthermore, inter-day accuracy ranged from 93.6 to 101.0% and from 102.3 to 111.4% in serum and urine samples, respectively. Intra-day precision %RSD of maleic acid in serum and urine samples was 13.8% or less, whereas the inter-day precision was 6.1% or less. The matrix effects were not found to be statistically significant (p = 0.9145 and p = 0.5378, respectively) based on the calculations of recovery functions. The collected serum and urine samples were analyzed using SPE-ID-LC-MS/MS. Our results reveal trace levels of maleic acid in the control rats; demonstrating that this method is capable of analyzing background levels of contaminants in biofluids with excellent sensitivity and specificity at parts-per-billion levels concentrations in complex matrices.
    Date: 2015-05
    Relation: Talanta. 2015 May;136:9-14.
    Link to: http://dx.doi.org/10.1016/j.talanta.2014.11.021
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0039-9140&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000350834700002
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84921527781
    Appears in Collections:[吳焜裕(2001-2008)] 期刊論文

    Files in This Item:

    File Description SizeFormat
    SDO0039914014009138.pdf1404KbAdobe PDF601View/Open


    All items in NHRI are protected by copyright, with all rights reserved.

    Related Items in TAIR

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback